GC-8100 Dimethyl Ether Analysis Dedicated Gas Chromatograph Detailed Information:
GC-8100 Dimethyl Ether Analysis Dedicated Gas Chromatograph
Reference Standards:
(1) CJ/T259-2007 "Dimethyl Ether for Urban Gas"
(2) HG/T3934-2007 "Dimethyl Ether"
The gas chromatograph is a cost-effective analytical instrument, controlled by a microcomputer with keyboard operation and LCD screen displaying a Chinese menu. It features high integration of electronic circuits, good reliability, simple operation, memory setting parameters that do not need to be reset each time, and is suitable for long-term operation.
Double-Person Three-Blow Air Shower Twist Drill Thermal Deformation Vicat Tester
The large column box and fan, together with the automatic rear door cooling system, enhance the cooling speed of the column box, truly achieving operation at room temperature of 5℃. The instrument can flexibly use capillary columns, glass columns, and stainless steel columns. It can perform isothermal and programmed temperature ramp operations.
Woven Bag Tensile Machine Magnetic Stirring Electric Heating Jacket Mettler pH Meter
Main Performance Features:
1. Large screen LCD display in Chinese, real-time display of temperature and operating conditions, clear and intuitive content,
truly achieving human-machine dialogue;
2. Self-check on startup, wide-range self-diagnostic function, accurately determining fault location and alarming;
3. Six-channel independent temperature control (vaporization chamber and capillary vaporization chamber can be controlled independently),
five-step programmed temperature ramp function;
Taper Shank Twist Drill Digital Display Stainless Steel Heating Plate Rapid Oil Water Content Determinator
4. Over-temperature protection function: if any channel exceeds the set temperature, the instrument automatically cuts off power and alarms;
5. Unique vertical heating device ensures more reliable sample vaporization, minimizing thermal radiation from the vaporization chamber,
ensuring very small temperature deviation within the column box;
6. Intelligent fuzzy control rear door system, automatically tracking temperature and dynamically adjusting
the air valve angle, achieving precise temperature control even near room temperature;
7. Equipped with a sampling device for packed column head injection, glass-lined injection, with a diaphragm cleaning
function for capillary split/non-split injection device, and can be installed with a gas sampler;
8. High-precision dual stable gas path, capable of installing four types of detectors simultaneously;
9. Optional electronic flow pressure display system with built-in workstation device.